- Product Details
Goodman 3 Ton 14 SEER Heat Pump Air Conditioner Condenser Air Handler Multi Zone
Count on the Goodman Heat Pump System to Exceed Expectations
The components of your Goodman ducted 3 ton 14 SEER central air conditioning and heat pump system are designed to bring you dependable performance, high energy efficiency and operating sound levels that are among the lowest in the HVAC industry. The Goodman GSZ140361 outdoor unit’s SmartShift™ defrost technology protects your compressor and enables worry-free use in colder climate zones. The matching ARUF37D14 indoor unit boasts a direct-drive, multi-speed motor which allows you to adjust the airflow for superior performance with your condensor.
Aesthetically-pleasing leather-embossed indoor unit cabinet
Maximum heat transfer owed to unique 5 mm condensing coil design
Outdoor unit is fully charged for 15 feet of tubing length
GSZ140361 | Outdoor Unit
With the design of the GSZ140361 heat pump, Goodman, one of the world’s largest heating and cooling manufacturers, has taken a smart design and made it better. The unit’s SMARTCOIL condenser coil copper tubing is smaller and smarter so the benefit is energy savings through less refrigerant use and lower energy consumption. The maintenance-free, heavy-gauge galvanized steel cabinet is enhanced with a steel louver coil guard.
Up to 9 HSPF
Copper tube / enhanced aluminum fin coil
Unique sound control top design
ARUF37D14 | Indoor Unit
The job of air conditioning isn’t just to cool or heat a room. You depend on it for dehumidification, air filtration and essential ventilation. The Goodman multi-position, multi-speed, ARUF37D14 air handler surpasses performance standards with notable attributes such as a multi-speed PSC motor, multiple airflow positions, minimal air leakage and grooved aluminum tubes mechanically bonded to aluminum ripple-edged fins for industry leading heat transfer.
All-aluminum evaporator coil
Transformer and blower time-delay
Foil-faced insulation reduces cabinet condensation
Additional Features
Outdoor Unit:
Attractive architectural gray powder-paint finish with 500-hour salt-spray test approval
Top and side maintenance access
Service ports and controls are accessible while unit is operating
When properly anchored, meets the 2010 Florida Building Code requirements for hurricane-type winds (Anchor bracket kits available.)
Factory-installed bi-flow liquid-line filter drier, suction line accumulator, compressor crankcase heater, high-capacity muffler
High- and low-pressure switches
Service valves with sweat connections and easy access to gauge ports
Contactor with lug connection
Ground lug connection
AHRI Certified
ETL Listed
Indoor Unit:
Flowrator for use in cooling and heat pump applications
21" depth for easier attic access
Nominal width is 24 ½”
3 kW - 25 kW electric heater kits are available as field-installed units but are not included
DecaBDE-free thermoplastic drain pan with secondary drain connections
Uses R-410A environmental-friendly refrigerant
Multiple electrical knockouts
Suitable for horizontal, vertical, upflow or downflow installations
Screwless sides and back prevent condensation
Three-hole condensate pan
Cabinet air leakage less than 2.0% at 1.0 inch H2O when tested in accordance with ASHRAE standard 193
Cabinet air leakage less than 1.4% at 0.5 inch H2O when tested in accordance with ASHRAE standard 193
AHRI certified
ETL listed
WHAT’S INCLUDED
Your Goodman Ducted Central Split System Air Conditioner Heat Pump from Heat & Cool Comes With:
GSZ140361| Outdoor Unit
ARUF37D14 | Indoor Unit
User’s Manual
Installation Manual
Manufacturer Warranty
MANUFACTURER WARRANTY
10-year parts limited warranty
How to size a heat pump
There are a couple of different methods you can use to find the right size heat pump for your home: Manual J and square footage. We'll discuss each of those in further detail below.
Manual J
Manual J is the industry standard of sizing a heat pump. It was established by the Air Conditioning Contractors of America to help determine the proper size heat pump for your home based on eight different factors. The eight factors that Manual J considers are:
- The local climate, including how many days per year you need heating and cooling
- Your home's square footage and layout
- How many windows you have and where they're located
- Your home's air filtration
- The insulation quality in your home
- How many people live in your home
- Your preferred temperature
- Heat-generating appliances in your home
Square footage
There are a lot of factors that go into calculating your heat pump size, and it can be complicated to determine how each of those affects your heat pump needs. Luckily, there's a simpler approach you can take to choose the right size heat pump.
In general, every 500 square feet of your home will require one ton of air conditioning capacity. Here are some guidelines to help you determine how many tons you'll need:
- 500 square feet: 1 ton
- 1,000 square feet: 2 tons
- 1,500 square feet: 3 tons
- 2,000 square feet: 4 tons
- 2,500 square feet: 5 tons
- 3,000 square feet: 6 tons
It's also important to know what each ton equals in BTUs, or British thermal units, which is the measurement used to determine heat pump sizing. Use this chart to help you determine the BTUs needed for your home:
Heat pump size guide
Home size (in square feet) | Heat pump size (in tons) | Heat pump size (in BTUs) |
---|---|---|
500 square feet | 1 ton | 12,000 BTUs |
1,000 square feet | 2 tons | 24,000 BTUs |
1,500 square feet | 3 tons | 36,000 BTUs |
2,000 square feet | 4 tons | 48,000 BTUs |
2,500 square feet | 5 tons | 60,000 BTUs |
3,000 square feet | 6 tons | 72,000 BTUs |
DOWNLOADS
Goodman Heat Pump Manufacturer Warranty
- Loading...